Fundamentals of gas appliance venting and ventilation 1985 american gas.
Furnace flue pipe code.
Always check your local state province codes and regulations.
Only fgv flue gas vent pvc certified to a specific standard ulc s636 may be used.
Where the system is routed to the outdoors through an existing masonry chimney containing flue products from another gas appliance or where required by local codes then 3 venting of type 29 4c stainless steel must be used in place of pvc material.
There will be a point where these factors counter balance the momentum of the flue gases.
Vent system capacity the volume of flue gases produced by a furnace directly depends on the btuh input of the furnace.
And why would you have to care about gas furnace vent pipe code.
Single wall metal pipe shall extend at least 2 feet 610 mm above the highest point where it passes through a roof of a building and at least 2 feet 610 mm higher than any portion of a.
8 national fuel gas code z223 1 16 00 and national fuel gas code handbook z223 2 47 00 american gas association a g a 1515 wilson boulevard arlington va 22209 also available from national fire protection association batterymarch park quincy ma 02269.
Single wall metal pipe shall terminate at least 5 feet 1524 mm in vertical height above the highest connected equipment draft hood outlet or flue collar.
Well the flue which is a term referring to the vent pipe is basically the important component from the furnace that will transport the emission from the combustion heating process to the outside area of the house.
Adhere to these instructions to ensure safe and proper furnace performance.
All piping must be installed in accordance with local codes and these instructions.
Pipe gravity and the cooling of the flue gases you can make the pipe too long.
9 is a typical clearance between a gas fired boiler or furnace flue connector and combustibles.
The length diameter and number of elbows of the vent flue pipe and combustion air pipe when applicable affects the performance of the furnace and must be carefully sized.
For example here in canada schedule 40 pvc dwv drain pvc may not be used.
See also condensing boilers furnaces.
Fire clearances required range from 6 to 36 depending on the equipment.
Masonry flue or shared flue venting.
There are different types grades of pvc on the market and some of them may not be allowed for use as flue gas exhaust.
Nfpa 211 reduces fire hazards by ensuring the safe removal of flue gases the proper installation of solid fuel burning appliances and the correct construction and installation of chimneys fireplaces and venting systems.